Post Frame Building - Product: Reflective Both Sides Post Frame Building - Roof - Retrofit - Bottom of Truss
Bottom of the Trusses Open Interior R-10* Heat Flow Down (and a Radiant Barrier) | R-3.7* Heat Flow Up
Please Note:
In addition to the stated R-value, this application also provides a
Radiant Barrier. As a result, a 96% reduction of the radiant energy
that ordinarily would be transmitted to the interior of the building is
blocked.
 Reflectix® Insulation products are a group of technologically advanced materials. They are ideal for new construction or retrofit applications in commercial, industrial, metal and post/frame buildings, along with many other DIY applications. When you think of insulation, you should think of Reflectix®. Our products are recognized for their thermal performance, easy installation, versatility, price and environmental friendliness.
Recommended Products:
Double Reflective Insulation Staple Tab, Reflective/Bubble/Bubble/Reflective - Roll
• ST24100 (24” x 100’) • ST48100 (48” x 100’)
Benefits:
• Easy to handle and install • Convenient roll sizes • Class A / Class 1 Fire Rating • Inhibits dew point condensation • Vapor retarder (0.02 perms) • Does not compress, collapse or disintegrate • Non-toxic / non-carcinogenic
Testing and Certification:
Reflectix® products are thoroughly tested at either nationally approved independent laboratories or leading universities. Tests are performed to current American Society of Testing and Materials (ASTM) standards when a standard exists. For a copy of an actual test report, please e-mail us at customerservice@reflectixinc.com or call at 800-879-3645.
Air Space Requirements:
Installation Instructions: Download Post Frame - Roof - Retrofit - Bottom of Trusses Installation Instructions.pdf
• Pre-installation inspection - Check the roof area for clutter, water sprinklers, conduit and lights. Sprinkler systems are especially important. All water pipes must be below the Reflectix® Reflective/Bubble/Bubble/Reflective Foil, Staple Tab product to prevent the possibility of freezing in the winter. • Nail 1”x 2” furring strips on the bottom of and perpendicular to the trusses on 22” centers. (Note: When truss spacing is 24” it is recommended to install the Reflectix® 24” or 48” product directly to the bottom cord of the truss.) • Butt the furring strips together and tape. Staple tape for reinforcement. • Staple the edges of the Reflectix® to the furring strips with the 3/4” tabs (so that they will overlap at the seam). • Tape the seams with a Reflectix® Foil Tape (goal is an air-tight, snug seam seal). • Tape any butt seams with Reflectix® Foil Tape, insure taped seam has a good full continuous bond. • Staple product at approximately 4” intervals down the middle of the sheet into the furring strip above.
* Includes thermal resistance of 1.32 UP and 4.55 DOWN for interior air film.
Calculation Disclaimer: All values are calculated based on the “ASHRAE Handbook of Fundamentals” heat flow up and down.
Important:
Additional Resources:
There are a wide variety of terms and words associated with the Reflectix® family of products. Those in common usage are itemized below in two categories - Products & Applications.
Products: Reflective Insulation, Radiant Barrier, Cathedral Ceiling Insulation, Crawl Space Insulation, Concrete Slab Insulation, Duct Insulation Indoors, Duct Insulation Outdoors, Duct Insulation Spacers, Expansion Joint, Knee Wall Insulation, Pipe Wrap Insulation, Radiant Floor Insulation, Return Air Duct Panning, Wall Insulation, Water Heater Insulation, Metal Building Insulation, Post and Frame Building Insulation, Foil Tape, Metalized Tape, White Poly Tape, Sill Sealer, Foil Insulation, Foil Radiant Barrier, Bubble Pack Insulation, Bubble Insulation, HVAC Insulation, Easy to Install Insulation, No Itch Insulation, Energy Saving Products, Energy Efficient Products. Also, Products/Terms within our industry include: Low-e Coatings, Radiant Barrier Paint, Radiation Control Coatings, Radiant Barrier Plywood, Radiant Barrier Decking, Radiant Barrier Chips, Radiant Barrier Tax Credit.
Applications: Attic, Behind Hot Water Radiator, Cathedral Ceiling, Concrete Slab, Crawl Space, Duct Indoors, Duct Outdoors, Expansion Joint, Garage Door, House Wrap, Knee Wall, Pipe Wrap, Radiant Floor, Snow Melt, Sill Sealer, Storage Buildings, Exterior Wall, Masonry Wall, Water Heater, Wine Room, Work Shop, Agricultural Building, Commercial Building, Return Air Panning, Metal Building Roof, Metal Building Wall, Post and Frame Building Roof, Post and Frame Building Wall.
|