House Wrap

Behind Brick R-3.4 Behind Aluminum or Vinyl Siding R-2.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. When…

Radiant Floor – In a Subfloor

R-4.6 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® has an insulating upgrade available for a radiant…

Radiant Floor – Concrete Slab

R-1.1 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Reflectix® Concrete Slab Insulation is an innovative, easy…

Big Bubble Duct Insulation R-8.0

R-8.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Expansion Joint

Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This durable, lightweight, closed-cell, foam expansion joint is the solution…

Duct Insulation Outdoor R‑8.0

R-8.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Duct Insulation Outdoor R‑6.0

R-6.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Duct Insulation Outdoor R‑5.6

R-5.6 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Duct Insulation Outdoor R‑4.2

R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Big Bubble Duct Insulation R‑6.0

R-6.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Reflectix® RAP (Bubble) Return Air Duct Panning

Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® RAP (Bubble) is an alternative to conventional sheet metal…

With Reflectix, I Can Camp in the Winter!

…winter months! It’s easy to cut, easy to install and easy to store! It took me a whole hour to do this and the best thing is that your 48″…

Post Frame Building – Roof – Retrofit – Bottom of Purlin

Bottom of the Purlins Metal Interior R-11 Heat Flow Down (and a Radiant Barrier) | R-5.1 Heat Flow Up Open Interior R-9.0* Heat Flow Down (and a Radiant Barrier) |…

Reflectix® RAP (Corrugated Sheet) Return Air Duct Panning

Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® RAP (Corrugated) is an alternative to conventional sheet metal…

Metal Building – Wall – Retrofit

Open Interior: R-3.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are a technologically advanced…

Duct Insulation R-5.6

R-5.6 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Post Frame Building – Roof – New

Below the Purlins Metal Interior R-11 Heat Flow Down (and a Radiant Barrier) | R-5.1 Heat Flow Up Open Interior R-9.0* Heat Flow Down (and a Radiant Barrier) | R-4.4*…

Metal Building – Wall – Retrofit

Open Interior: R-4.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are a group of…

Metal Building – Wall – New

Metal Interior with a 3/4” Thermal Break: R-8.2 Open Interior with a 3/4” Thermal Break: R-6.0 Metal Interior with a Nominal 3/4” Drape in Product (No Thermal Break): R-5.9 Open…

Metal Building – Roof – Retrofit

Open Interior with 1”x 2” Furring R-11* Heat Flow Down (and a Radiant Barrier) R-4.4* Heat Flow Up Please Note: In addition to the stated R-value, this application also provides…

Metal Building – Roof – New

Open Interior with 3/4” Thermal Breaks R-10* Heat Flow Down (and a Radiant Barrier) R-4.5* Heat Flow Up Open Interior without Thermal Breaks and a Nominal 3/4” Drape R-7.6* Heat…

Metal Building – Wall – New

Open Interior with a 3/4” Thermal Break: R-4.6 Open Interior with a Nominal 3/4” Drape in Product (No Thermal Break): R-3.7 Note: Installation instructions and illustrated drawings are recommendations only,…

Snow Melt System

R-1.1 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Reflectix® Concrete Slab Insulation is an innovative, easy…

Metal Building – Roof – Retrofit

Open Interior with 1”x 2” Furring R-7.5* Heat Flow Down R-3.6* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the…

Metal Building – Roof – New

Open Interior with 3/4” Thermal Breaks R-5.5* Heat Flow Down R-3.4* Heat Flow Up Open Interior without Thermal Breaks and a Nominal 3/4” Drape R-4.0* Heat Flow Down R-3.2* Heat…

Performance Information

…Insulation, Radiant Barrier and Foil Tape can be installed in environments with a range of -30 degrees to 180 degrees F. Reflective Insulation: What is Reflectivity? Reflectivity is a material…

Frequently Asked Questions

…a range of -30 degrees to 180 degrees F. Reflective Insulation: What is Reflectivity? Reflectivity is a material “characteristic” that is quantified as the percentage of radiant energy that a…

Reflectix Safety Guidelines

…be careful when working with large pieces of Reflectix® on windy days. When installing Reflectix® on bright sunny days, it is best to wear sun glasses. Do not work in…

Water Heater

R-4.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This application is a great option to reduce the…

Duct Insulation R-6.0

R-6.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Pipe Wrap

R-2.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Reflective/Bubble products for pipe wrap applications are the…

A 25 Year Old Roll of Reflectix Tape

…products over the years, and find them to be top quality at a fair price. Thank you for being a company with integrity. Best Wishes, — Jim C., Janesville, WI…

Attic

Radiant Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® products are an excellent, energy-efficient choice for…

Post Frame Building – Wall – New

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Outside the Girts Metal Interior: R-5.5 Open Interior: R-4.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local…

Post Frame Building – Wall – Retrofit

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix®…