Search Results

Search results for “Cialis Approved Pharmacy ⭐ www.HealthMeds.online ⭐ Buy Cialis 10mg - Cheap Cialis Online”

Post Frame Building – Wall – Retrofit

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix®…

Post Frame Building – Roof – New

Below the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Above the Purlins Open Interior R-3.8* Heat Flow Down | R-3.5* Heat Flow Up Note: Installation…

Wall – Masonry

R-3.7, R-7.0 and a Vapor/Moisture Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Do-It-Yourselfer has several…

Wall – Exterior (2 x 6)

R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Post Frame Building – Roof – Retrofit – Bottom of Purlin

Bottom of the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

Wall – Exterior (2 x 4)

R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Post Frame Building – Roof – Retrofit – Bottom of Truss

Bottom of the Trusses Open Interior R-6.6* Heat Flow Down | R-3.0* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

Snow Melt System

Increased Efficiency in a Snow Melt System Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. For the Do-It-Yourselfer,…

Radiant Floor – Wood Joists

Up to R-21 and a Radiant Reflector (Maximum Benefit Application) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Radiant Floor – Concrete Slab

R-1.1 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. For the Do-It-Yourselfer, Reflectix® has an insulating upgrade available…

Post Frame Building – Wall – New

Inside the Girts Open Interior: R-4.2 Outside the Girts Open Interior: R-3.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of…

Knee Wall

R-16 and a Radiant Reflector (with R-13 Fiberglass Batt) R-19 and a Radiant Reflector (with R-13 Fiberglass Batt and 0.75” Furring (on Back of Knee Wall)) Note: Installation instructions and…

Crawl Space R-16

R-16 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. When considering options for a crawl space, Reflectix® Reflective/Bubble…

Radiant Floor – Concrete Slab

R-1.1 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. For the Do-It-Yourselfer, Reflectix® has an insulating upgrade available…

Concrete Slab

R-1.1 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. For the Do-It-Yourselfer, Reflectix® has an insulating product specifically…

Cathedral Ceiling

Northern Zone of the USA – With Reflectix® Below the Mass Insulation: R-7.0 Summer & R-1.0 Winter and a Vapor/Moisture Barrier Southern Zone of the USA – With Reflectix® Above…

Attic

Radiant Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® products are an excellent, energy-efficient choice for…

Crawl Space R-21

R-21 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix is now offering a dramatically improved performance application…

Work Shop

Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…

Wine Room

R-3.7 (1” x 2” Furring with 1 Air Space) R-7.0 (2” x 2” Furring with 2 Air Spaces in Addition to a Vapor/Moisture Barrier) Note: Installation instructions and illustrated drawings…

Water Heater

R-4.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This application is a great option for the Do-It-Yourselfer…

Wall – Masonry

R-3.7, R-7.0 and a Vapor/Moisture Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Do-It-Yourselfer has several…

Wall – Exterior (2 x 6)

R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Wall – Exterior (2 x 4)

R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Storage Building

Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…

Snow Melt System

Increased Efficiency in a Snow Melt System Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. For the Do-It-Yourselfer,…

Radiant Floor – Wood Joists

Up to R-21 and a Radiant Reflector (Maximum Benefit Application) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Post Frame Building – Roof – Retrofit – Bottom of Truss

Bottom of the Trusses Open Interior R-10* Heat Flow Down (and a Radiant Barrier) | R-3.7* Heat Flow Up Please Note: In addition to the stated R-value, this application also…