R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…
Search Results
Search results for “best way to buy cheap mexico airline tickets phone number 1-800-299-7264”
Wall – Exterior (2 x 4)
Post Frame Building – Roof – Retrofit – Bottom of Purlin
Bottom of the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…
Wall – Exterior (2 x 6)
R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…
Wall – Masonry
R-3.7, R-7.0 and a Vapor/Moisture Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Do-It-Yourselfer has several…
Post Frame Building – Roof – New
Below the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Above the Purlins Open Interior R-3.8* Heat Flow Down | R-3.5* Heat Flow Up Note: Installation…
Post Frame Building – Wall – Retrofit
Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix®…
Post Frame Building – Wall – New
Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Outside the Girts Metal Interior: R-5.5 Open Interior: R-4.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local…
Wine Room
R-3.7 (1” x 2” Furring with 1 Air Space) R-7.0 (2” x 2” Furring with 2 Air Spaces in Addition to a Vapor/Moisture Barrier) Note: Installation instructions and illustrated drawings…
Wall – Masonry
R-3.7, R-7.0 and a Vapor/Moisture Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Do-It-Yourselfer has several…
Radiant Floor – In a Subfloor
R-4.6 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® has an insulating upgrade available for a radiant…
Single Reflective Insulation
…Systems Product Codes/Sizes: Specific applications within a category will contain Recommended Products that are best suited for a particular installation. Please refer to specific application webpages for this more detailed…
Agricultural / Livestock Buildings
Poultry Houses Stables Dairy / Milking Facilities Hog Farms Reflectix offers a wide range of applications and products for installation in Agricultural and Livestock Buildings. Depending on the structure of…
Duct Insulation (Indoor and Outdoor)
…R-4.2 Duct Insulation – R-5.6 Duct Insulation – R-6.0 Duct Insulation – R-8.0 Product Codes/Sizes: Specific applications within a category will contain Recommended Products that are best suited for a…
Concrete Slab Insulation
…In a Concrete Slab Snow Melt Product Codes/Sizes: Specific applications within a category will contain Recommended Products that are best suited for a particular installation. Please refer to specific application…
Attic
Radiant Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® products are an excellent, energy-efficient choice for…
Behind Hot Water Radiator
R-3 and a Radiant Reflector Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. In order to increase the…
Cathedral Ceiling
Northern Zone of the USA – With Reflectix® Below the Mass Insulation: R-7.0 Summer & R-1.0 Winter and a Vapor/Moisture Barrier Southern Zone of the USA – With Reflectix® Above…
Crawl Space R-16
R-16 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. When considering options for a crawl space, Reflectix® Reflective/Bubble…
Wall – Exterior (2 x 6)
R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…
Duct Insulation R-4.2
R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Utilizing Reflectix® to enhance the efficiency of your existing…
Garage Door
R-3.0 (Also Provides a Radiant Barrier Benefit in Warmer Climates) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….
Knee Wall
R-16 and a Radiant Reflector (with R-13 Fiberglass Batt) R-19 and a Radiant Reflector (with R-13 Fiberglass Batt and 0.75” Furring (on Back of Knee Wall)) Note: Installation instructions and…
Pipe Wrap
R-2.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Reflective/Bubble products for pipe wrap applications are the…
Double Reflective Insulation
…Wall – Exterior (2 x 6) Wall – Masonry Product Codes/Sizes: Specific applications within a category will contain Recommended Products that are best suited for a particular installation. Please refer…
Storage Building
Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…
Wall – Exterior (2 x 4)
R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…
Post Frame Building – Roof – Retrofit – Bottom of Truss
Bottom of the Trusses Open Interior R-10* Heat Flow Down (and a Radiant Barrier) | R-3.7* Heat Flow Up Please Note: In addition to the stated R-value, this application also…