Search Results

Search results for “when does airlines give cheap airplane tickets phone number 1-800-299-7264”

Metal Building – Wall – New

Open Interior with a 3/4” Thermal Break: R-4.6 Open Interior with a Nominal 3/4” Drape in Product (No Thermal Break): R-3.7 Note: Installation instructions and illustrated drawings are recommendations only,…

Radiant Floor – Wood Joists

Up to R-21 and a Radiant Reflector (Maximum Benefit Application) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Reflectix® RAP (Corrugated Sheet) Return Air Duct Panning

Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® RAP (Corrugated) is an alternative to conventional sheet metal…

Water Heater

R-4.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This application is a great option to reduce the…

An Old Concept

…significant part of the heat transfer. Reflective Insulation vs. Mass Insulation A foam cup “insulates” a cup of coffee as mass insulation does and attains an actual R-value. The reflective…

Metal Building – Roof – New

Open Interior with 3/4” Thermal Breaks R-5.5* Heat Flow Down R-3.4* Heat Flow Up Open Interior without Thermal Breaks and a Nominal 3/4” Drape R-4.0* Heat Flow Down R-3.2* Heat…

Metal Building – Roof – Retrofit

Open Interior with 1”x 2” Furring R-7.5* Heat Flow Down R-3.6* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the…

Metal Building – Wall – Retrofit

Open Interior: R-4.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are a group of…

Metal Building – Wall – Retrofit

Open Interior: R-3.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are a technologically advanced…

2018 I-RIM Conference Costa Rica a Great Success!

…About RIMA-I and the Advanced Building Code Coalition (ABCC) – Bobby Byrd New Digital Experiences – Mario Vargas Does the Presence of a Radiant Barrier Increase the Chance of a…

Metal Building – Roof – New

Open Interior with 3/4” Thermal Breaks R-10* Heat Flow Down (and a Radiant Barrier) R-4.5* Heat Flow Up Open Interior without Thermal Breaks and a Nominal 3/4” Drape R-7.6* Heat…

Metal Building – Roof – Retrofit

Open Interior with 1”x 2” Furring R-11* Heat Flow Down (and a Radiant Barrier) R-4.4* Heat Flow Up Please Note: In addition to the stated R-value, this application also provides…

Metal Building – Wall – New

Metal Interior with a 3/4” Thermal Break: R-8.2 Open Interior with a 3/4” Thermal Break: R-6.0 Metal Interior with a Nominal 3/4” Drape in Product (No Thermal Break): R-5.9 Open…

Radiant Floor – In a Subfloor

R-4.6 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® has an insulating upgrade available for a radiant…

Post Frame Building – Roof – New

Below the Purlins Metal Interior R-11 Heat Flow Down (and a Radiant Barrier) | R-5.1 Heat Flow Up Open Interior R-9.0* Heat Flow Down (and a Radiant Barrier) | R-4.4*…

Post Frame Building – Roof – Retrofit – Bottom of Purlin

Bottom of the Purlins Metal Interior R-11 Heat Flow Down (and a Radiant Barrier) | R-5.1 Heat Flow Up Open Interior R-9.0* Heat Flow Down (and a Radiant Barrier) |…

House Wrap

Behind Brick R-3.4 Behind Aluminum or Vinyl Siding R-2.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. When

Post Frame Building – Wall – New

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Outside the Girts Metal Interior: R-5.5 Open Interior: R-4.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local…

Expansion Joint

Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This durable, lightweight, closed-cell, foam expansion joint is the solution…

Post Frame Building – Wall – New

Inside the Girts Open Interior: R-4.2 Outside the Girts Open Interior: R-3.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of…

Post Frame Building – Wall – Retrofit

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix®…

Post Frame Building – Roof – New

Below the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Above the Purlins Open Interior R-3.8* Heat Flow Down | R-3.5* Heat Flow Up Note: Installation…

Post Frame Building – Roof – Retrofit – Bottom of Purlin

Bottom of the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

Post Frame Building – Roof – Retrofit – Bottom of Truss

Bottom of the Trusses Open Interior R-6.6* Heat Flow Down | R-3.0* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

Radiant Floor – Wood Joists

Up to R-21 and a Radiant Reflector (Maximum Benefit Application) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Reflectix is FANTASTIC!

…a pleasure to use! I want to wrap many more areas and it looks great exposed too! Thank you for an actual product that works as you say it does….

Expansion Joint

Easy to Handle and Install Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This durable, lightweight, closed-cell, foam…

Attic

Radiant Barrier Note: This is an example of 1 of 3 installation methods. Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility…

Post Frame Building – Wall – Retrofit

Inside the Girts Open Interior: R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are…

Work Shop

Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…

Water Heater

R-4.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This application is a great option for the Do-It-Yourselfer…

Storage Building

Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…

Radiant Floor – Wood Joists

Up to R-21 and a Radiant Reflector (Maximum Benefit Application) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Expansion Joint

Easy to Handle and Install Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This durable, lightweight, closed-cell, foam…

Agricultural / Livestock Buildings

Poultry Houses Stables Dairy / Milking Facilities Hog Farms Reflectix offers a wide range of applications and products for installation in Agricultural and Livestock Buildings. Depending on the structure of…