R-5.6


Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer.
Reflectix® Duct Insulation is an alternative to other types of fibrous insulation products. Ease of handling and quick installation make Reflectix® the first choice when selecting insulation for round or rectangular ductwork in HVAC systems. The product provides an R-5.6 when installed with a 0.375” air gap between the duct and the insulation.
function getWR360PopupSkin(){return 'light_clean';}Product Description
Reflectix® Duct Insulation consists of two layers of highly reflective film (96% reflectivity) that are bonded to two tough layers of polyethylene. Two inner layers of insulating bubbles resist conductive heat flow while a center layer of polyethylene gives Reflectix® high reliability and strength. The product has a tape running the length of the roll for easy identification by code officials. The tape identifies the manufacturer and ASTM Testing: Reflectix® Duct Insulation • ASTM E84 • Class A / Class 1 • ASTM C411 Passed
Benefits
- Wrap rectangular or round ductwork in HVAC applications
 - Heating costs can be greatly reduced
 - Eliminate unnecessary heat loss / gain and air leakage
 - Helps to ensure consistent temperatures
 - Non-toxic / non-carcinogenic
 - Fiber-free
 - Lowers heating and cooling costs year-round
 - Reflects 96% radiant heat
 - Costs less to install
 - Lightweight and clean
 - Does not promote nesting of insects or rodents
 - Resists growth of fungi, mold and mildew
 - Does not require protective clothing or respirators to install
 - ISO 9001:2015 certified manufacturing location
 - Not affected by moisture or humidity
 
Part Numbers and Sizes
- HVBP12050 (12”x 50’)
 - HVBP16050 (16”x 50’)
 - HVBP24050 (24”x 50’)
 - HVBP36050 (36”x 50’)
 - HVBP48050 (48”x 50’)
 - HVBP60050 (60”x 50’)
 - HVBP12100 (12”x 100’)
 - HVBP16100 (16”x 100’)
 - HVBP24100 (24”x 100’)
 - HVBP36100 (36”x 100’)
 - HVBP48100 (48”x 100’)
 - HVBP60100 (60”x 100’)
 - HVBP12125 (12”x 125’)
 - HVBP16125 (16”x 125’)
 - HVBP24125 (24”x 125’)
 - HVBP36125 (36”x 125’)
 - HVBP48125 (48”x 125’)
 - HVBP60125 (60”x 125’)
 
Technical Data
- Temperature Range: -30 to 180 F
 - Nominal Thickness: 5/16 inch (.312)
 - Weight: 0.771 oz./sq. ft.
 - Flame Spread Index (ASTM E 84): Less than 25
 - Smoke Developed Index (ASTM E 84): Less than 50
 - Fire Rating: Class A/Class 1
 - Linear Shrinkage: None
 - Reflectance (IR): 96%
 - Water Vapor Transmission (ASTM E 96): 0.02
 - Puncture Resistance: 60 lb./in.
 - Mold and Mildew: No Growth
 - Emittance: 0.04
 - Tensile Strength: 3.7 N/mm
 - Pliability: No Cracking
 - Hot Surface Performance: Passed (250 F)
 
Note: Not for use in direct contact on surface temperatures that are 180 F or greater.
Testing and Certification
- Thermal Performance ASTM C335
 - Hot Surface Performance ASTM C411
 - Flame Spread and Smoke Density ASTM E84
 - Fungus Resistance Mil-Std 810B Method 508
 - Pliability Test ASTM C1224
 - Sound Absorption Test ASTM C423 and ASTM E795
 - Sound Transmission Loss ASTM E90 and ASTM E413
 - Water Vapor Transmission ASTM E96
 - Tensile Strength ASTM D751
 - Bleeding and Delamination ASTM C1668
 - Intertek: Surface Burning Characteristics of Building Materials ASTM E84-08 (Taped Joint Detail) Test Report # 3166908SAT-012
 - Intertek: Surface Burning Characteristics of Building Materials ASTM E84-08 (Unslit) Test Report # 3166908SAT-011
 - R&D Services: Resistance to the Growth of Fungi ASTM C1338-00 Test Report # RD072713FR
 - State of California
 - State of California Licensed Insulation Manufacturer
 - State of Minnesota: Filed with Minnesota Insulation Standards Program
 - R&D Services Emittance Testing ASTM C1371
 - R&D Services: Physical Properties Sheet Width, Length, Pliability, Water Vapor Permanence and Aged Water Vapor Permanence
 - R&D Services: Water Vapor Transmission Test ASTM-E96 (Dessicant Method)
 
Installation Instructions
Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer.
Spacer Wrapped in a Candy Cane Fashion
Spacer: HVSPW02025 – Reflectix® Spiral Pipe Wrap 2”x 25’
- Refer to the two diagrams above.
 - Make sure all sheet metal joints, seams and penetrations are sealed.
 - Wrap and secure spacer material to the duct in a candy cane fashion. Proceed down the duct in one direction with a repeat of the wrap at 12” intervals. Use a UL 181 approved tape to fasten the spacer in place.
 - Verify the circumference of the duct with the spacer strip in place.
 - Cut the Reflectix® product to this length plus 1”.
 - Wrap the product around the duct and securely tape the linear and circumference seams (overlapping 1”- 2”) with a UL 181 approved tape (goal is an air-tight, snug seam seal).
 - Do not leave any exposed duct or space where air can enter between the duct and the Reflectix®.
 
Please Note Regarding Hangers:
Strap Hanger: Wrap Reflectix® with the seam at the hanger. Tape seam tightly around hanger.
Saddle Hanger: Make sure that there is a spacer below the hanger between the insulation and the duct to prevent the insulation from touching the duct.
Important
Review These Important Safety Guidelines Prior to Installation:
- ALWAYS check local building codes before installing Reflectix®.
 - ALWAYS check the area you are insulating and make any needed repairs. Any worn wiring should be replaced before you begin installing Reflectix®.
 - ALWAYS make sure work areas are well ventilated and well lighted.
 - ALWAYS use eye protection when operating a staple gun.
 - ALWAYS use caution and common sense when using a staple gun. Be aware of electrical wiring locations. Stapling into a wire can cause severe shock or death. NEVER staple into electrical wiring.
 - ALWAYS be careful when working with large pieces of Reflectix® on windy days.
 - When installing Reflectix® on bright sunny days, it is best to wear sun glasses.
 - Do not work in areas such as attics when temperatures are too hot.
 - Please Note: The intention of these Installation Instructions and 3-D renderings are for the sole purpose of illustrating the correct location and relative position of the Reflectix® products in specific building assemblies. The correct construction methods and techniques are the responsibility of the installer or contractor. The methods outlined are recommendations on location of the Reflectix® products as a guideline. There are no claims on the part of Reflectix, Inc. that these building assemblies are finite standards or meet building code requirements (as they can vary by region).
 
Photos
Pictured: 1. Double Reflective Insulation, 2. Taping the Seam with a UL 181 Tape
							
							
							